Iron Assay Kit -Colorimetric-

£192.00 exc. VAT

SKU: I291-10 Category:

Tissue Iron Detection

  • Detect iron in tissue samples
  • Standard samples for quantifying the content of Fe2+ and Fe3+ are included
  • A convenient calculation sheet for calculating iron content is provided

Description

Iron is one of the most important metallic elements in living organisms. In recent years, an iron-dependent mode of cell death, ferroptosis, has emerged, and research on intracellular iron ions has attracted increased attention.
The Iron Assay Kit-Colorimetric is a kit for measuring the amount of iron ions (Fe²⁺ and Fe³⁺) in tissue. It enables data acquisition in approximately 2 h from sample pretreatment to the measurement of iron ion concentration.
The concentration of Fe²⁺ in a tissue sample can be determined by adding Ferene S, which is a chromogenic dye for Fe²⁺, to the tissue lysate and measuring its absorbance. By using the reducing agent included in the kit to reduce Fe³⁺ in the sample to Fe²⁺, the concentrations of total iron and Fe³⁺ in the sample can also be determined.

Ferroptosis Analysis Products

Product Name Target Ditection Properties
FerroOrange Intracellular Fe2+ Microscopy, Plate reader
Ex: 543 nm / Em: 580 nm
Mito-FerroGreen Mitochondrial Fe2+ Microscopy
Ex: 505 nm / Em: 535 nm
Lyso-FerroRed Lysosomal Fe2+ Microscopy, FCM, Plate reader
Ex: 551 nm / Em: 571 nm
Iron Assay Kit -Colorimetric- Fe2+ and Fe3+ Plate reader
Colorimetric, λ: 593 nm
Liperfluo Lipid Peroxide Microscopy, FCM
Ex: 488 nm / Em: 500-550 nm
Lipid Peroxidation Probe
-BDP 581/591 C11-
Lipid Peroxidation
Process
Microscopy, FCM, Plate reader
Pre-reaction, Ex: 488 nm / Em: 510-550 nm
Post-reaction, Ex: 561 nm / Em: 600-630 nm
MDA Assay Kit Malondialdehyde Plate reader
Fluorescence, Ex: 540 nm / Em: 590 nm
Colorimetric, λ: 532 nm
Cystine Uptake Assay Kit Cystine uptake Plate reader
Ex: 485 nm / Em: 535 nm
GSSG/GSH Quantification Kit GSSG and GSH Plate reader
Colorimetric, λ: 405 nm

Technical info

Iron Detection Kit and Staining Reagents

Select the appropriate reagent based on your experimental method and detecting equipment.

Lyso-FerroRed FerroOrange Mito-FerroGreen Iron Assay Kit -Colorimetric-
Intracellular localization Lysosome Intracellular Mitochondria ー (Tissue)
Detection properties Fluorometric
λex : 551 nm, λem : 571 nm
Fluorometric
λex : 543 nm, λem : 580 nm
Fluorometric
λex : 505 nm, λem : 535 nm
Colorimetric
593 nm
Supported
devices
(filter)
Microscope, Plate reader,
Flow cytometry(TRITC)
Microscope, Plate reader(Cy3) Microscope(FITC, GFP) Plate reader
Target Lysosomal Fe2+ in live cells Intracellular Fe2+ in live cells Mitochondrial Fe2+ in live cells Fe2+ and Fe3+ in tissue
Usage count 35 nmol can be used for 17 assays at 35 mm dish
(final concentration 1 µmol/l).
1 tube (24 µg) can be used for 17 assays at 35 mm dish
(final concentration 1 µmol/L)
1 set (50 µg x 2) can be used for 10 assays at 35 mm dish
(final concentration 5 µmol/L)
50 tests
(Make standard curve and
detect Fe2+ only: 4 samples,
detect Fe2+ and Fe3+: 2 samples)

Ferrous Ion Selectivity

Experimental example: Detection of Fe2+ and Fe3+ in liver sample

Using this kit, we measured the amounts of Fe2+ and Fe3+ in mouse liver. We confirmed that 100 mg of mouse liver contained 2.51 nmol of Fe2+, 3.05 nmol of Fe3+, and a total iron content of 5.56 nmol.

 

Pack Size